Latest Revisions - 2018 Edition

Specifications | Design

Specifications

The table below summarizes the changes made with the latest revisions to the SUDAS Standard Specifications. There is also a link below that contains the entire revision packets. However, if your manual is not updated to the 2017 Edition, the revisions below will not coordinate with your manual.

Complete packet of revisions

Division

Section

Pages

Summary of Change

1 1010, 1.03 4 Updated joint venture definition to reflect recent changes in Iowa law.
1020, 1.01 1 Revised qualification of the bidders to reflect recent changes in Iowa law.
1030, 1.01, D 1-2 Revised to reflect recent changes in Iowa law.
1040, 1.05 ALL Added specifications requirements for use of stringless paving equipment to provide information to the contractor and the equipment requirements, as well as the construction staking. Affected pages that followed.
1050, 1.15 (new) 6 Added specifications requirements for use of stringless paving equipment to provide information to the contractor and the equipment requirements, as well as the construction staking.
1070, 3.01, C 12 Revised to reflect recent changes in Iowa law.
1070, 3.06, D 18 Minor spelling correction.
1080, 1.03, C 3 Revised to reflect recent changes in Iowa law.
2 2010, 3.06, B, 2 17 Corrected reference error.
3 3010, 2.05, A & B 7 Added a standard gradation option (Iowa DOT Gradation No. 13).
Figure 3010.101 (SW-101) 1 Replaced SUDAS and Iowa DOT logos.
Figure 3010.104 (SW-104) 1 Replaced SUDAS and Iowa DOT logos.
Figure 3010.105 (SW-105) 1 Replaced SUDAS and Iowa DOT logos.
3020, 2.02, B, 1 2 Updated to align with Iowa DOT changes in welder certification.
4 Table of Contents iii Updated to reflect changes made in Division 4.
4010, 1.08, D, 1, c & J 1-4 Minor revisions.
Figures 4010.201-203 (SW-201 through 203) ALL Replaced SUDAS and Iowa DOT logos.
4020, 1.08, D 2 Updated reference.
4020, 3.06, C, 2 8 Deleted “O-ring” from the last line and added ASTM reference.
Figure 4020.211 (SW-211) 1 Removed "invert" callout, retitled, and replaced SUDAS and Iowa DOT logos.
4060, 3.05, A 7 Changed "PVC" to "flexible" and added "excluding ductile iron pipe.”
5 5010, 2.01, A 4 Deleted all references to AWWA C905 due to combining of AWWA C900 and C905.
5010, 3.07, C, 3 10 Deleted “O-ring” from the last line and added ASTM reference.
5020, 1.08, I-K 3 Added new measurement and payment options for valve and hydrant removals.
6 Table of Contents i Updated to reflect changes made in Division 6.
6010 ALL Replace ENTIRE SECTION with enclosed pages (INCLUDING figures). Changed “invert” to “concrete fillet”; added a cored opening option for storm sewer connections to existing manholes or intakes; added a 4 inch curb height option to the open-throat curb intake figures; replaced SUDAS and Iowa DOT logos.
6030, 3.04 ALL Minor corrections.
7 Table of Contents ALL Updated to reflect changes made in Division 7.
7010 ALL Replace ENTIRE SECTION with enclosed page (EXCLUDING figures). Removed overlay information; removed the restriction for use of fly ash and slag only with ready mix concrete; added the use of laser guided screeds and concrete pumping; added stringless paving; added intermediate aggregate; expanded mix design to add C-SUD mixes.
Figure 7010.101 (PV-101) 1 Corrected notes 22 and 23 to align with industry standards.
7011 (new) ALL Added new section for PCC overlay projects.
7020 3-10 Removed overlay information.
7021 (new) ALL Added new section for HMA overlay projects.
7030, 3.04, A & 3.08 7-12 Added criteria for when the Engineer would check form work; added testing requirements.
7040 ALL Replace ENTIRE SECTION with enclosed pages (INCLUDING figures). Updated information on partial depth patches; added a subsection and figure on dowel bar retrofit for PCC pavements.
7080, 1.07, A 1-4 Revised to reflect recent changes in Iowa law.
8 Table of Contents iii-iv Added new pages to table of contents for addition of Section 8030.
8010, 2.05, C, 3 13 Revised to reflect current manufacturing.
Figure 8010.102 (TS-102) 1-2 [Begins on the back of Figure 8010.101]. Revised to reflect current manufacturing.
8020, 3.01, B, 4 6 Minor correction.
8030 (new) ALL Added a new section to provide standard temporary traffic control layouts. Figures included!
9 Table of Contents i-ii Updated to reflect changes made in Division 9.
9010, 2.07-3.05 13-21 Revised language to match current practice and the Iowa DOT.
9040, 2.20-3.13 13-20 Updated requirements to reflect current construction practices and made other minor revisions.
Figure 9040.102 1 Updated requirements to reflect current construction practices.
9050, 1.08, C 2 Updated reference.
9070, 1.08, D, E, & F 2 Updated reference.
9071, 1.08, B, D, & E 2 Updated reference.
9072, 1.08 & 2.01 1-2 Updated reference.
9080, 2.01, A 3 Updated reference.
11 11,010, 1.01 & 1.03 1-2 Deleted qualification requirement per recent change in Iowa law.
11,010, 3.03, F 8 Added stringless paving.

Design

The table below summarizes the changes made with the latest revisions to the SUDAS Design Manual. There is also a link below that contains the entire revision packets. However, if your manual is not updated to the 2017 Edition, the revisions below will not coordinate with your manual.

Complete packet of revisions

Chapter

Section

Pages

Summary of Change

1

 

Table of Contents ii Updated to reflect changes made in Chapter 1.

1D-1, I through K

15-60

Revised "Items to be Specified" list based on SUDAS Specifications revisions. Updated "Incidental or Included Items" list. Updated "Bid Items" list.

2

2A-1, D 5-7 Corrected table and figure numbers; updated Iowa Administrative Code reference.
2D-2 3 Updated Table 2D-2.01.
4 4C-1, D 3 Clarified when to use slide type valve boxes and when to use screw type boxes.
5 Table of Contents i-v Updated to reflect changes made in Chapter 5.
5B-1 1 Corrected mistake in page header.
5C-1 1 Corrected mistake in page header.
5C-1, Table 5C-1.02 7 Revised footnote #15.
5C-2 1 Corrected mistake in page header.
5D-1 ALL Updated information on binder selection for northern tiers of counties, intermediate and base layers, and for overlays.
5E-1, C, 2 5-6 Removed the restriction for use of fly ash and slag only with ready mix concrete.
5E-1, I, 2, c and J 13-15 Added information on joint durability (C-SUD) mixes to match recent research and clarified information on admixtures.
5G-2, C, 3 5-6 Revised language to match a specifications change.
5G-6 through 5O-1 ALL REMOVE remaining sections of Chapter 5 and replace with enclosed pages. Added new sections for jointing of PCC roundabouts, automated machine guidance, and overlays. Renumbered various sections to better organize the chapter with the new additions.
7 7E-4, A and B 1-4 Updated requirements to reflect current construction practices.
7E-7 3-4 Updated specifications figure number references.
7E-9 3-4 Updated specifications figure number reference.
7E-10 5-6 Updated specifications figure number references.
7E-11 3-4 Updated specifications figure number reference.
7E-12 3-8; 15-16 Updated specifications figure number references.
7E-13 3-4 Updated specifications figure number reference.
7G-1 ALL Updated references.
9 Table of Contents i Updated to reflect changes made in Chapter 9.
9B-5, C 3-8 Added depth of bury information for polypropylene pipe.
9C-1, B 1 Corrected table numbering and reference in paragraph.
9D-1, B 1 Updated reference.
12 Table of Contents ii Updated to reflect changes made in Chapter 12.
12B-3 ALL Corrected bike guide reference; added more detailed design information on buffered and separated bicycle lanes; corrected bike vs. bicycle terminology; added references.
13 Table of Contents i Updated to reflect changes made in Chapter 13.
13A-1, B 1 Updated references.
13B-1 ALL Corrected mistake in page header; added interim change to Warrant 7.
14 14D-1 1 Updated reference.

 

Page last updated: December 8, 2017